Risk of damage to lines |
Lines may become damaged by moving or hot components. |
– | Route lines in their original positions. |
– | Ensure that there is sufficient clearance to moving or hot components. |
|
Safety instructions for using extraction and charging equipment
Before connecting the charging system to the air
conditioning system, make sure that all existing shut-off valves
are closed.
Before the charging equipment is decoupled from the air
conditioning system, ensure that the process has ...
Removing and installing upper part of sump
Special tools and workshop equipment
required
Allen key, long reach -T10058-
Hand drill with plastic brush
Eye protection
...
Connecting air conditioner service station for measuring and checking
Depending on the type of equipment chosen, there may be
variations in the required procedure; therefore always follow
the user's manual for the equipment being used.
Note