VW Golf manuals

Volkswagen Golf Service & Repair Manual: Performing maintenance test

  WARNING
It is not permissible to test or charge batteries whose colour indicator is light yellow. Do not slave/jump start the vehicle!
Danger of explosion when checking and charging or slave/jump starting.
These batteries must be renewed.
–  Select “Maintenance test” in the menu.
–  Connect scanner.
  Note
If no scanner is available, write vehicle identification number on test printout by hand.
–  Scan in vehicle identification number.
–  Select “On battery terminal” or “On jump-start point”.
–  Scan in 2D code of battery or manually select type and make in menu.
–  Measure temperature. Hold temperature sensor about 5 cm above terminal connection until temperature stabilises.
–  Start test.
–  Print out test log if necessary.
   
Perform guarantee test
  WARNING It is not permissible to test or charge batteries whose colour indicator is light yellow. Do not slave/jum ...

Perform service test
  Note The print-out may vary depending on software version. Observe the → operating manual of the battery tester ...

Other materials:

Removing and installing bracket for onboard supply control unit -J519-, RHD vehicles
Removing –  With ignition switched off, disconnect earth cable from battery → Chapter. –  Remove dash panel → General body repairs, interior; Rep. gr.70. ...

Adjusting front axle toe
Special tools and workshop equipment required     Torque wrench -V.A.G 1332-   Socket -V.A.G 1332/9-   ...

Charging battery in maintenance mode with battery charger -VAS 5095 A-
  WARNING Danger of injury! Observe warning notices and safety regulations → Chapter!   WARNING It is not permissible ...