Volkswagen Golf Service & Repair Manual: Spraying the evaporator with the suction feed spray-gun -V.A.G 1538- and
spray lance
Spray the evaporator with Contra Sept directly using a spray
lance (approx. 10 bar). Contra Sept neutralises microbes and
bacteria directly at the evaporator. |
In order to enable access to the evaporator, some
preliminary work and different spray lances are necessary, e.g. V.A.G
1538/5; V.A.G 1538/6 or V.A.G 1538/7. |
Vehicle-specific instructions for user are provided with the
evaporator cleaning solution D 600 100 A2. |
Current equipment and spray lances
→ ServiceNet Function “Search” |
|
The ultrasonic air conditioner cleaning unit -VAS 6189A-
must be placed in the front-passenger footwell and sprays the
agent Aero-Clean. Aero-Clean neutralises microb ...
For vehicles that have connections on both
low-pressure and high-pressure sides of refrigerant circuit
Connecting air conditioner s ...
Other materials:
Run-flat tyres, repair work
WARNING
Tyres with run-flat properties must be replaced
after they have been run deflated.
Adhere to the special assembly instructions
→ Chapter.
...
Warning and indicator lamps
The warning and indicator lamps indicate various warnings , faults or certain
functions. Some warning and indicator lamps light up when the ignition is switched
on and should go out once the engine is running or the vehicle is in motion.
Depending on the vehicle equipment level, additio ...
Checking pistons and cylinder bores
Checking piston
–
Using a micrometre, measure approx. 10 mm from the lower
edge, perpendicular to the piston pin axis.
Maximum deviation from nominal dimension: 0.04 mm
...