Volkswagen Golf Service & Repair Manual: Connecting air conditioner service station
For vehicles that have connections on both
low-pressure and high-pressure sides of refrigerant circuit |
|
Connecting air conditioner service
station for measuring and checking |
– |
Connect air conditioner service station to power supply. |
– |
Connect quick-release coupling adapters to charging hoses
for air conditioner service station (handwheels not turned
inwards, i.e. hand shut-off valves not open). |
– |
Switch on air conditioner service station and evacuate
charging hoses (necessary only if there is air in the charging
hoses). |
– |
Switch off air conditioner service station. |
– |
Unscrew sealing caps from service connections (with valve). |
– |
Connect air conditioner service station via service
connections to the vehicle refrigerant circuit using
quick-release coupling adapter. |
– |
Turn handwheel of quick-release coupling adapter inwards
only far enough to ensure that valves on service connections are
open (check using a pressure gauge; do not overstress valves). |
– |
Perform the intended measuring and checking work. |
|
Spray the evaporator with Contra Sept directly using a spray
lance (approx. 10 bar). Contra Sept neutralises microbes and
bacteria directly at the evaporator.
...
Other materials:
Removing and installing rear seat backrest
Special tools and workshop equipment
required
Torque wrench -V.A.G 1331
Removing
–
Remove bench seat
→ Ch ...
12 V socket
Removing and installing 12 V socket
Caution
If excessive force is exerted on sockets without
illumination, the retaining sleeve may be damaged.
Only illuminated sockets (cigarette lighter) ...
Operation
First read and observe the introductory information
and safety warnings The traffic sign recognition system is supported in various
countries . Please remember this when travelling abroad.
Display of traffic signs
Speed limit signs and no-overtaking signs with accompanying additional si ...