Volkswagen Golf Service & Repair Manual: Connecting air conditioner service station
For vehicles that have connections on both
low-pressure and high-pressure sides of refrigerant circuit |
|
Connecting air conditioner service
station for measuring and checking |
– |
Connect air conditioner service station to power supply. |
– |
Connect quick-release coupling adapters to charging hoses
for air conditioner service station (handwheels not turned
inwards, i.e. hand shut-off valves not open). |
– |
Switch on air conditioner service station and evacuate
charging hoses (necessary only if there is air in the charging
hoses). |
– |
Switch off air conditioner service station. |
– |
Unscrew sealing caps from service connections (with valve). |
– |
Connect air conditioner service station via service
connections to the vehicle refrigerant circuit using
quick-release coupling adapter. |
– |
Turn handwheel of quick-release coupling adapter inwards
only far enough to ensure that valves on service connections are
open (check using a pressure gauge; do not overstress valves). |
– |
Perform the intended measuring and checking work. |
|
Spray the evaporator with Contra Sept directly using a spray
lance (approx. 10 bar). Contra Sept neutralises microbes and
bacteria directly at the evaporator.
...
Other materials:
Repairing corrugated pipe
Special tools and workshop equipment
required
Hot air blower -VAS 5179- or
Hot air blower -V.A.G 1416/- or
Hot air blower -VAS 1978/14-
...
Removing and installing upper transverse link, front-wheel drive
Special tools and workshop equipment
required
Torque wrench -V.A.G 1332-
Removing
–
Loosen wheel bolts.
–
...
Blender
Designation:
Blender -LLS MAX 009-
Issued 10.2008
Product description
The blender -LLS MAX 009- is used to achieve homogenous
paint transitions in the blending/edge areas bet ...
© 2016-2025 Copyright www.vwgolf.org