Volkswagen Golf Service & Repair Manual: Connecting air conditioner service station
For vehicles that have connections on both
low-pressure and high-pressure sides of refrigerant circuit |
|
Connecting air conditioner service
station for measuring and checking |
– |
Connect air conditioner service station to power supply. |
– |
Connect quick-release coupling adapters to charging hoses
for air conditioner service station (handwheels not turned
inwards, i.e. hand shut-off valves not open). |
– |
Switch on air conditioner service station and evacuate
charging hoses (necessary only if there is air in the charging
hoses). |
– |
Switch off air conditioner service station. |
– |
Unscrew sealing caps from service connections (with valve). |
– |
Connect air conditioner service station via service
connections to the vehicle refrigerant circuit using
quick-release coupling adapter. |
– |
Turn handwheel of quick-release coupling adapter inwards
only far enough to ensure that valves on service connections are
open (check using a pressure gauge; do not overstress valves). |
– |
Perform the intended measuring and checking work. |
|
Spray the evaporator with Contra Sept directly using a spray
lance (approx. 10 bar). Contra Sept neutralises microbes and
bacteria directly at the evaporator.
...
Other materials:
Introduction
This chapter contains information on the following subjects:
→ Technical requirements
→ Mechanically positioned ball coupling
→ Fitting a bicycle carrier on the mechanically positioned ball coupling
→ Hitching and connecting the trailer
...
Aligning exhaust system free of tension
Procedure
The exhaust system must be aligned when cold.
Note
The -arrow- points forwards.
–
Loosen bolt connections for front clamp
...
Absorbent glass mat battery
Maintenance-free battery with a contained electrolyte and no
colour indicator
Lead-acid battery where the electrolyte is contained within
a microscopic glass mat (AGM). The battery is sealed and fitted
with valves.
...
© 2016-2022 Copyright www.vwgolf.org