VW Golf manuals

Volkswagen Golf Service & Repair Manual: If there is still refrigerant in the refrigerant circuit

  Drain refrigerant circuit.
–  Remove defective part, purge with compressed air and collect escaping refrigerant oil.
–  A quantity of fresh refrigerant oil equal to the quantity of refrigerant oil that has been blown out (plus 20 cm3 for the evaporator, plus 10 cm3 for the condenser, refrigerant pipes and refrigerant hoses) should be poured into the new component.
–  Renew restrictor. Depending on vehicle
–  Assemble refrigerant circuit, evacuate and charge.
   
If the refrigerant circuit was completely empty
Remove defective part. –  Remove air conditioner compressor. –  Remove oil drain screw from air conditione ...

Renewing air conditioner compressor
  Note On vehicles equipped with an electrical air conditioner compressor, de-energise the high-voltage system before removing the air conditioner compre ...

Other materials:

2-pack HS Performance clear coat
Designation: 2-pack HS Performance clear coat -LZK 769 K06 A5- Issued 08.2012 Product description 2-pack HS Performance clear coat is a high-gloss, VOC compliant, high-solid ...

Filling the tank with petrol, diesel or E85
Fig. 188 Open tank flap with tank cap attached to the holder First read and observe the introductory information and safety warnings Switch off the engine, ignition, mobile telephone and auxiliary heater before filling the tank and leave them switched off during refilling. Opening the ...

Ultrasonic air conditioner cleaning unit -VAS 6189A
The ultrasonic air conditioner cleaning unit -VAS 6189A- must be placed in the front-passenger footwell and sprays the agent Aero-Clean. Aero-Clean neutralises microbes and bacteria in the heater and air conditioner unit. The device is p ...