Detecting leaks in refrigerant circuit using leak detecting system -VAS
6196- or leak detecting system -VAS 6201- or a later model
Blowing through refrigerant circuit with compressed air and nitrogenPressing tyre off wheel rim
Unscrew valve insert.
Note
If bonded wheel trims are fitted, treat them with great
care. The surface is susceptible to scratches.
If the wheel trim is damaged, renew wheel rim.
...
Assembly overview – tank flap unit, e-Golf
1 -
Fuel tank flap
–
Removing and installing
→ Chapter.
2 -
Tank flap unit
Removing and installing.
3 -
Bolt
1.5 Nm
4 -
Immediate char ...
Safety precautions for when working on vehicles with air conditioning and
when handling refrigerant R134a
Air conditioning service station -VAS 6007A- (and further
service stations currently available)
→ Workshop equipment
WARNING
It is recommended that a bottle co ...