Removing and installing Bowden cable for remote release mechanism for seat
backrestDraining air conditioner service station
Note
If it becomes necessary to drain the air conditioner service
station (e.g. because contaminated refrigerant was extracted),
all filters and dryers are to be renewed as a rule. Do not take
the filters and dryers out of their airtight p ...
Safety precautions when working on high-voltage system
Danger to life due to high voltage
The high-voltage system is under high voltage. There is a risk of
severe or fatal injury due to electric shock.
–
Persons with life-preserving or other electronic medical devices in
or on their body must not perf ...
Removing and installing upper part of sump
Special tools and workshop equipment
required
Allen key, long reach -T10058-
Hand drill with plastic brush
Eye protection
...