Volkswagen Golf Service & Repair Manual: Refrigerant circuit with expansion valve

A- low-pressure side of the refrigerant circuit.
B- high-pressure side of the refrigerant circuit.

Refrigerant circuit with expansion valve
 

     
Component Overall state of the refrigerant Pressure (in bar) Temperature in degrees Celsius
-1- evaporator, from inlet to outlet Vapour approx. 1.2 bar → Remark approx. -7°C → Remark
    (approx. 1.8 bar) → Remark approx. -1°C → Remark
-2- Air conditioning system compressor A-side Gas approx. 1.2 bar → Remark approx. -1°C
    (approx. 1.8 bar) → Remark (approx. +1°C) → Remark
-3- Air conditioning system compressor B-side Gas approx. 14 bar approx. +65°C
-4- Condenser Gas, vapour, liquid approx. 14 bar at outlet approx. + 55°C
-5- Receiver Liquid approx. 14 bar approx. +55°C
-6- Extraction and charging valve, B side Liquid approx. 14 bar approx. +55°C
-7-Expansion valve Liquid, released into vapour approx. 14 bar approx. +55°C, reduced to -7°C
-8- Extraction and charging valve, A side Gas approx. 1.2 bar → Remark approx. -7°C → Remark
    (approx. 1.8 bar) → Remark approx. -1°C → Remark
 
1)  The pressure in refrigerant circuits with regulating air conditioner compressor is held to approx. 2 bar despite changing heat transport and differing engine speeds. This applies however only within the rated range of the air conditioner compressor; if the rated range of the air conditioner compressor is exceeded, the pressure will increase → Chapter.
2)  The temperature in refrigerant circuits with regulating air conditioner compressor is held within the regulation range of the air conditioner compressor despite changing heat transport and differing engine speeds. This applies however only within the rated range of the air conditioner compressor; if the rated range of the air conditioner compressor is exceeded, the temperature will increase. → Chapter
3)  Measured values for air conditioning systems with two evaporators
  Note
Air conditioning system compressors that do not self-regulate their load are switched off by the respective control unit via the air conditioner compressor regulating valve -N280- when an evaporator temperature less than 0°C is sensed.
In vehicles with air conditioner compressor regulating valve -N280-, the pressure on the low-pressure side is varied by activating the valve.
   
Pressures and temperatures in the refrigerant circuit
  WARNING When working on the refrigerant circuit, observe generally applicable safety rules and the Regulations for ...

Refrigerant circuit with restrictor and reservoir
Arrows show the direction of refrigerant flow. A- low-pressure side of the refrigerant circuit. B- high-pressure side of the refrigerant circuit.   ...

Other materials:

Instructions for work on underbody and stone chip protection
  Note   The structure of the underbody and stone chip protection is to be reconstructed to conform to the original condition in appearance and thickness.   Water drainage holes must remain clear. ...

EU tyre label, objectives
Reducing fuel consumption Increasing road safety Reducing traffic noise The EU tyre label provides the end-user with important information on the properties of the tyre. It does not ill ...

Removing and installing coolant pipes at heat exchanger (Valeo)
  Note There are different designs and makes of heater and air conditioning unit. The individual components of the various heaters and air conditioning units are similar but not identical (distinguishing features → Chapter). The c ...

© 2016-2024 Copyright www.vwgolf.org