VW Golf manuals

Volkswagen Golf Service & Repair Manual: Supplementary heating mode

Once the coolant temperature has reached approx. 84 °C, the control unit switches to energy-saving control mode. If the coolant temperature continues to rise above approx. 88 °C, the control unit switches to the controlled waiting period. If the coolant temperature does not drop below approx. 76 °C within 15 minutes during the controlled waiting period, the heater unit will initiate the start procedure into the standard control mode when the coolant temperature does drop below approx. 76 °C.
   
Functional description
The auxiliary and supplementary heater can be started by means of the remote control, the instant heating button or appropriate programming in the central monitor. Th ...

Auxiliary heater mode
Switching on auxiliary heater mode in vehicles with manual air conditioning: –  Press instant heating button-1-.   ...

Other materials:

Checking inertia reel (locking mechanism)
The inertia reel has two locking functions.   The first locking function is triggered by the belt being jerked out of the reel (belt extension acceleration). Test 1 –  Pull belt o ...

Removing and installing B-pillar trim on front door
  Note Removal and installation are described only for the left side. Removal and installation of the right side are similar. Removing –  Run door window down to bottom position. –  Pull window channel -3- in area ...

Charging totally discharged battery with battery charger -VAS 5903-
  WARNING Danger of injury! Observe warning notices and safety regulations → Chapter!   WARNING It is not permissible ...