VW Golf manuals

Volkswagen Golf Service & Repair Manual: Supplementary heating mode

Once the coolant temperature has reached approx. 84 °C, the control unit switches to energy-saving control mode. If the coolant temperature continues to rise above approx. 88 °C, the control unit switches to the controlled waiting period. If the coolant temperature does not drop below approx. 76 °C within 15 minutes during the controlled waiting period, the heater unit will initiate the start procedure into the standard control mode when the coolant temperature does drop below approx. 76 °C.
   
Functional description
The auxiliary and supplementary heater can be started by means of the remote control, the instant heating button or appropriate programming in the central monitor. Th ...

Auxiliary heater mode
Switching on auxiliary heater mode in vehicles with manual air conditioning: –  Press instant heating button-1-.   ...

Other materials:

Assembly overview - selector mechanism, manufacturer ZF
1 -  Handle with selector cover Do not remove handle without reason. Emergency release from position P → Chapter Removing and installing → Chapter Moving push button to installation positio ...

Types of protective tube on uniform Lambda probes
  Note In addition to identifying by way of the part number, the protective tube can also be used as a means of identification. Type D1, 6 openings at 3.5 mm each     Only used ...

Run-flat tyres, PAX, checking
When checking a tyre, look out especially for the following criteria: Surface erosion or ripples on the inner side (inflation pressure was too low or not sufficient for the load)     ...