VW Golf manuals

Volkswagen Golf Service & Repair Manual: Safety instructions for using extraction and charging equipment

Before connecting the charging system to the air conditioning system, make sure that all existing shut-off valves are closed.
Before the charging equipment is decoupled from the air conditioning system, ensure that the process has finished. The reason for this is to ensure that no refrigerant oil escapes into the atmosphere.
After the cleaned refrigerant from the charging system has been charged into an external pressurised gas cylinder, close the hand shut-off valves on the bottle and the charging system.
Do not expose charging system to moisture or use it in a wet environment.
Before performing service work and the charging system, disconnect the current supply.
To reduce danger of fire, avoid using extension cords. If nevertheless it is necessary to use an extension cable, use an extension cable with a cross-section of at least 2.5 mm2.
In case of fire, remove external cylinder.
If entrained oil from the air conditioning system suction accumulator is trapped in the measuring beaker supplied, be sure subsequently to pour the oil into a container that can be sealed, since the oil contains a small amount of refrigerant. Refrigerants must not be released into the environment.
When the air conditioner service station is switched off, it must be secured against rolling away.
   
Handling pressure tanks
Secure vessels against falling over! Secure standing cylinders against falling over and lying cylinders from rolling away. ...

Safety precautions for when working on vehicles with air conditioning and when handling refrigerant R134a
Air conditioning service station -VAS 6007A- (and further service stations currently available) → Workshop equipment ...

Other materials:

Assembly overview - alternator with sliding bushes
1 -  Alternator -C- Removing and installing → Chapter Checking → Chapter Removing and installing poly V-belt pulley → Chapter Removing and installing voltage reg ...

Safety precautions when working on fuel supply system
Risk of injury due to highly-pressurised fuel. The fuel system is under high pressure. Risk of injury due to fuel which may spurt out. –  Release high pressure before opening the fuel system.       & ...

Safety markings on battery
Safety markings on battery 1. -  Fires, sparks, naked flames and smoking are prohibited when handling batteries. Avoid sparks as well as electrostatic discharge when working with cables and electrical units. Avoid short ci ...